Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Heliyon ; 10(3): e25295, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38327415

RESUMEN

Catheter ablation (CA) remains the cornerstone alternative to cardioversion for sinus rhythm (SR) restoration in patients with atrial fibrillation (AF). Unfortunately, despite the last methodological and technological advances, this procedure is not consistently effective in treating persistent AF. Beyond introducing new indices to characterize the fibrillatory waves (f-waves) recorded through the preoperative electrocardiogram (ECG), the aim of this study is to combine frequency- and time-domain features to improve CA outcome prediction and optimize patient selection for the procedure, given the absence of any study that jointly analyzes information from both domains. Precisely, the f-waves of 151 persistent AF patients undergoing their first CA procedure were extracted from standard V1 lead. Novel spectral and amplitude features were derived from these waves and combined through a machine learning algorithm to anticipate the intervention mid-term outcome. The power rate index (φ), which estimates the power of the harmonic content regarding the dominant frequency (DF), yielded the maximum individual discriminant ability of 64% to discern between individuals who experienced a recurrence of AF and those who sustained SR after a 9-month follow-up period. The predictive accuracy was improved up to 78.5% when this parameter φ was merged with the amplitude spectrum area in the DF bandwidth (AMSALF) and the normalized amplitude of the f-waves into a prediction model based on an ensemble classifier, built by random undersampling boosting of decision trees. This outcome suggests that the synthesis of both spectral and temporal features of the f-waves before CA might enrich the prognostic knowledge of this therapy for persistent AF patients.

2.
Entropy (Basel) ; 26(1)2023 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-38248154

RESUMEN

Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated concomitantly with other cardiac interventions through the Cox-Maze procedure. This highly invasive intervention is still linked to a long-term recurrence rate of approximately 35% in permanent AF patients. The aim of this study is to preoperatively predict long-term AF recurrence post-surgery through the analysis of atrial activity (AA) organization from non-invasive electrocardiographic (ECG) recordings. A dataset comprising ECGs from 53 patients with permanent AF who had undergone Cox-Maze concomitant surgery was analyzed. The AA was extracted from the lead V1 of these recordings and then characterized using novel predictors, such as the mean and standard deviation of the relative wavelet energy (RWEm and RWEs) across different scales, and an entropy-based metric that computes the stationary wavelet entropy variability (SWEnV). The individual predictors exhibited limited predictive capabilities to anticipate the outcome of the procedure, with the SWEnV yielding a classification accuracy (Acc) of 68.07%. However, the assessment of the RWEs for the seventh scale (RWEs7), which encompassed frequencies associated with the AA, stood out as the most promising individual predictor, with sensitivity (Se) and specificity (Sp) values of 80.83% and 67.09%, respectively, and an Acc of almost 75%. Diverse multivariate decision tree-based models were constructed for prediction, giving priority to simplicity in the interpretation of the forecasting methodology. In fact, the combination of the SWEnV and RWEs7 consistently outperformed the individual predictors and excelled in predicting post-surgery outcomes one year after the Cox-Maze procedure, with Se, Sp, and Acc values of approximately 80%, thus surpassing the results of previous studies based on anatomical predictors associated with atrial function or clinical data. These findings emphasize the crucial role of preoperative patient-specific ECG signal analysis in tailoring post-surgical care, enhancing clinical decision making, and improving long-term clinical outcomes.

3.
J Pers Med ; 12(10)2022 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-36294860

RESUMEN

Catheter ablation (CA) is a commonly used treatment for persistent atrial fibrillation (AF). Since its medium/long-term success rate remains limited, preoperative prediction of its outcome is gaining clinical interest to optimally select candidates for the procedure. Among predictors based on the surface electrocardiogram, the dominant frequency (DF) and harmonic exponential decay (γ) of the fibrillatory waves (f-waves) have reported promising but clinically insufficient results. Hence, the main goal of this work was to conduct a broader analysis of the f-wave harmonic spectral structure to improve CA outcome prediction through several entropy-based measures computed on different frequency bands. On a database of 151 persistent AF patients under radio-frequency CA and a follow-up of 9 months, the newly introduced parameters discriminated between patients who relapsed to AF and those who maintained SR at about 70%, which was statistically superior to the DF and approximately similar to γ. They also provided complementary information to γ through different combinations in multivariate models based on lineal discriminant analysis and report classification performance improvement of about 5%. These results suggest that the presence of larger harmonics and a proportionally smaller DF peak is associated with a decreased probability of AF recurrence after CA.

4.
Physiol Meas ; 40(7): 075003, 2019 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-31239416

RESUMEN

OBJECTIVE: The most relevant source of signal contamination in the cardiac electrophysiology (EP) laboratory is the ubiquitous powerline interference (PLI). To reduce this perturbation, algorithms including common fixed-bandwidth and adaptive-notch filters have been proposed. Although such methods have proven to add artificial fractionation to intra-atrial electrograms (EGMs), they are still frequently used. However, such morphological alteration can conceal the accurate interpretation of EGMs, specially to evaluate the mechanisms supporting atrial fibrillation (AF), which is the most common cardiac arrhythmia. Given the clinical relevance of AF, a novel algorithm aimed at reducing PLI on highly contaminated bipolar EGMs and, simultaneously, preserving their morphology is proposed. APPROACH: The method is based on the wavelet shrinkage and has been validated through customized indices on a set of synthesized EGMs to accurately quantify the achieved level of PLI reduction and signal morphology alteration. Visual validation of the algorithm's performance has also been included for some real EGM excerpts. MAIN RESULTS: The method has outperformed common filtering-based and wavelet-based strategies in the analyzed scenario. Moreover, it possesses advantages such as insensitivity to amplitude and frequency variations in the PLI, and the capability of joint removal of several interferences. SIGNIFICANCE: The use of this algorithm in routine cardiac EP studies may enable improved and truthful evaluation of AF mechanisms.


Asunto(s)
Función Atrial , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas/métodos , Corazón/fisiología , Procesamiento de Señales Asistido por Computador , Análisis de Ondículas , Humanos
5.
Physiol Meas ; 39(11): 115006, 2018 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-30475747

RESUMEN

OBJECTIVE: The electrocardiogram (ECG) is currently the most widely used recording to diagnose cardiac disorders, including the most common supraventricular arrhythmia, such as atrial fibrillation (AF). However, different types of electrical disturbances, in which power-line interference (PLI) is a major problem, can mask and distort the original ECG morphology. This is a significant issue in the context of AF, because accurate characterization of fibrillatory waves (f-waves) is unavoidably required to improve current knowledge about its mechanisms. This work introduces a new algorithm able to reduce high levels of PLI and preserve, simultaneously, the original ECG morphology. APPROACH: The method is based on stationary wavelet transform shrinking and makes use of a new thresholding function designed to work successfully in a wide variety of scenarios. In fact, it has been validated in a general context with 48 ECG recordings obtained from pathological and non-pathological conditions, as well as in the particular context of AF, where 380 synthesized and 20 long-term real ECG recordings were analyzed. MAIN RESULTS: In both situations, the algorithm has reported a notably better performance than common methods designed for the same purpose. Moreover, its effectiveness has proven to be optimal for dealing with ECG recordings affected by AF, since f-waves remained almost intact after removing very high levels of noise. SIGNIFICANCE: The proposed algorithm may facilitate a reliable characterization of the f-waves, preventing them from not being masked by the PLI nor distorted by an unsuitable filtering applied to ECG recordings with AF.


Asunto(s)
Artefactos , Fibrilación Atrial/diagnóstico , Suministros de Energía Eléctrica , Electrocardiografía , Procesamiento de Señales Asistido por Computador , Análisis de Ondículas , Relación Señal-Ruido
6.
Ann Biomed Eng ; 45(8): 1890-1907, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28421394

RESUMEN

Atrial fibrillation (AF) is the most common arrhythmia in clinical practice with an increasing prevalence of about 15% in the elderly. Despite other alternatives, catheter ablation is currently considered as the first-line therapy for the treatment of AF. This strategy relies on cardiac electrophysiology systems, which use intracardiac electrograms (EGM) as the basis to determine the cardiac structures contributing to sustain the arrhythmia. However, the noise-free acquisition of these recordings is impossible and they are often contaminated by different perturbations. Although suppression of nuisance signals without affecting the original EGM pattern is essential for any other later analysis, not much attention has been paid to this issue, being frequently considered as trivial. The present work introduces the first thorough study on the significant fallout that regular filtering, aimed at reducing acquisition noise, provokes on EGM pattern morphology. This approach has been compared with more refined denoising strategies. Performance has been assessed both in time and frequency by well established parameters for EGM characterization. The study comprised synthesized and real EGMs with unipolar and bipolar recordings. Results reported that regular filtering altered substantially atrial waveform morphology and was unable to remove moderate amounts of noise, thus turning time and spectral characterization of the EGM notably inaccurate. Methods based on Wavelet transform provided the highest ability to preserve EGM morphology with improvements between 20 and beyond 40%, to minimize dominant atrial frequency estimation error with up to 25% reduction, as well as to reduce huge levels of noise with up to 10 dB better reduction. Consequently, these algorithms are recommended as a replacement of regular filtering to avoid significant alterations in the EGMs. This could lead to more accurate and truthful analyses of atrial activity dynamics aimed at understanding and locating the sources of AF.


Asunto(s)
Algoritmos , Artefactos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Diagnóstico por Computador/métodos , Modelos Cardiovasculares , Análisis de Ondículas , Simulación por Computador , Humanos , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
7.
Comput Methods Programs Biomed ; 131: 157-68, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27265056

RESUMEN

BACKGROUND AND OBJECTIVES: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and a growing healthcare burden worldwide. It is often asymptomatic and may appear as episodes of very short duration; hence, the development of methods for its automatic detection is a challenging requirement to achieve early diagnosis and treatment strategies. The present work introduces a novel method exploiting the relative wavelet energy (RWE) to automatically detect AF episodes of a wide variety in length. METHODS: The proposed method analyzes the atrial activity of the surface electrocardiogram (ECG), i.e., the TQ interval, thus being independent on the ventricular activity. To improve its performance under noisy recordings, signal averaging techniques were applied. The method's performance has been tested with synthesized recordings under different AF variable conditions, such as the heart rate, its variability, the atrial activity amplitude or the presence of noise. Next, the method was tested with real ECG recordings. RESULTS: Results proved that the RWE provided a robust automatic detection of AF under wide ranges of heart rates, atrial activity amplitudes as well as noisy recordings. Moreover, the method's detection delay proved to be shorter than most of previous works. A trade-off between detection delay and noise robustness was reached by averaging 15 TQ intervals. Under these conditions, AF was detected in less than 7 beats, with an accuracy higher than 90%, which is comparable to previous works. CONCLUSIONS: Unlike most of previous works, which were mainly based on quantifying the irregular ventricular response during AF, the proposed metric presents two major advantages. First, it can perform successfully even under heart rates with no variability. Second, it consists of a single metric, thus turning its clinical interpretation and real-time implementation easier than previous methods requiring combined indices under complex classifiers.


Asunto(s)
Fibrilación Atrial/diagnóstico , Frecuencia Cardíaca , Fibrilación Atrial/fisiopatología , Electrocardiografía , Humanos
8.
J Clin Exp Dent ; 7(4): e483-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26535094

RESUMEN

BACKGROUND: There exists a relation between the presence and location of the micro-gap and the loss of peri implant bone. Several authors have shown that the treatments based on the use of platform switching result in less peri-implant bone loss and an increased tissue stability. The purpose of this study was to analyse the effect of the platform switching on the distribution of stresses on the peri-implant bone using the finite element method. MATERIAL AND METHODS: A realistic 3D full-mandible finite element model representing cortical bone and trabecular bone was used to study the distribution of the stress on the bone induced by an implant of diameter 4.1 mm. Two abutments were modelled. The first one, of diameter 4.1 mm, was used in the reference model to represent a conventional implant. The second one, of diameter 3.2 mm, was used to represent the implant with platform switching. Both models were subjected to axial and oblique masticatory loads. RESULTS: The analyses showed that, although no relevant differences can be found for the trabecular bone, the use of platform switching reduces the maximum stress level in the cortical bone by almost 36% with axial loads and by 40% with oblique loads. CONCLUSIONS: The full 3D Finite Element model, that can be used to investigate the influence of other parameters (implant diameter, connexion type, …) on the biomechanical behaviour of the implant, showed that this stress reduction can be a biomechanical reasons to explain why the platform switching seems to reduce or eliminate crestal bone resorption after the prosthetic restoration. KEY WORDS: Dental implant, platform switching, finite element method.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...